Search results for "Bond strength"
showing 10 items of 125 documents
Effect of various dentin disinfection protocols on the bond strength of resin modified glass ionomer restorative material.
2017
Background Disinfection of dentin surface prior to any restorative therapy is important for the longevity of the treatment rendered. However, these dentin disinfection methods should itself not interfere with the adhesion of the restorative material. Therefore the aim of this study was to determine the effect of various dentin disinfection protocols on the shear bond strength (SBS) of resin modified glass ionomer cement (RMGIC). Material and methods The occlusal surface of 40 extracted premolars were trimmed to obtain a flat dentinal surface and was randomly divided into four groups. CTRL was the control group; NaOCl was 1% sodium hypochlorite disinfection group; CHX was 2% chlorhexidine di…
The effect of photodynamic therapy and polymer solution containing nano-particles of Ag /ZnO on push-out bond strength of the sealers AH-Plus and MTA…
2017
BACKGROUND The aim of this in vitrostudy was to examine and compare the effect of photodynamic therapy and solution containing nano particles Ag/ZnO on adhesion of endodontic sealers to dentinal walls of human root canal. MATERIAL AND METHODS Ninty single-rooted human teeth were selected and their clinical crown was cut from the cemento-enamel junction zone. Canals were prepared by RaCe rotary system and the smear layer was removed using 17% EDTA and 5.25% NaOCl. Samples were randomly divided into two groups of AH Plus and MTA Fillapex based on the sealer type and each group based on antimicrobial method was divided into two sub-groups of photodynamic therapy and polymer containing nano par…
Effect of rinsing time and surface contamination on the bond strength of silorane-based and dimethacrylate-based composites to enamel
2018
Background The aim of this study was to assess whether saliva contamination and rinsing time for 15, 30, and 60 seconds, affects the shear bond strength of silorane and methacrylate-based composites to enamel. Material and Methods Two light cure resin, P60 (3M ESPE) and Filtek LS Silorane were tested. 120 sound premolars were randomly divided into four groups of 30 teeth based on composite type with or without saliva contamination after etching and rinsing. Each group was further divided into three subgroups according to their rinsing time. Then a cylinder of the composite was bonded to the enamel and Shear bond strength was assessed. To determine the failure mode, the bonded surfaces were …
Effect of Smear Clear and Some Other Commonly Used Irrigants on dislodgement resistance of Mineral Trioxide Aggregate to Root Dentin
2016
Background This study aimed to assess the push-out bond strength of mineral trioxide aggregate (MTA) to root canal dentin after irrigation with Smear Clear in comparison with 2.5% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX) and saline as commonly used root canal irrigants. Material and Methods The coronal and mid-root areas of maxillary anterior teeth were horizontally sectioned into one-millimeter thick slices. The root canal lumen of dentinal slices was dilated using a diamond bur with 1.3 mm diameter. After the application of MTA, the samples were incubated in 100% humidity for 10 minutes and were then randomly divided into four groups (n=20) and immersed in Smear Clear, 2.5% NaO…
Comparative evaluation of shear bond strength of universal dental adhesives : an in vitro study
2017
Background Patient demand for tooth colored restorations and desire for minimally invasive restorations have made composites an indispensable part of the restorative process. An important factor affecting the intra-oral performance of composite restorations is bonding. Material and methods Ninty six freshly extracted molar teeth were collected and occlusal 3mm is removed using a diamond disc to expose dentine. Following with samples were divided in to two main groups (self-etch & total etch). Each main group is again sub divided in to three groups each according to bonding agent used (Tetric N- Bond Universal, Single Bond Universal, Tetric N Bond Total etch in total etch group and Clear Fil…
Comparison of the shear bond strength of 3D printed temporary bridges materials, on different types of resin cements and surface treatment
2019
Background Thus, purpose of this study was to compare the shear bond strength of the resin cement and the resin modified glass ionomer cement on 3D printed temporary material for crowns and bridges in combination with different surface treatment modalities. Material and methods Test specimens VarseoSmile Temp material (Bego, Bremen, Germany) (n=64) in the form of rectangular blocks (n=32) and cylindrical test specimens (n=32) were printed using the Varseo S 3D printer (Bego, Bremen, Germany). The specimens were divided into 4 groups, with 8 specimens of each kind. Two groups (n=16 pairs) were blasted with Perlablast® Micro [PM] 50µm (Bego, Bremen, Germany) and two groups (n=16 pairs) were b…
Effect of self-etching primer/adhesive and conventional bonding on the shear bond strength in metallic and ceramic brackets
2011
Introduction: Bracket debonding from the tooth surface is a common problem in fixed orthodontics. The aims of the present study were to assess the bond strength and failure sites in two ways of bonding technique, with metallic and ceramic brackets. Material and Methods: One hundred premolars were assigned to 4 groups of 25 each: Group A, metallic brackets/ conventional procedure; Group B, metallic brackets/Transbond XT; Group C, ceramic brackets/conventional procedure; and Group D, ceramic brackets/Transbond XT. Transbond XT composite paste was used for bracket bonding and cured by conventional light-cure device. Specimens were subjected to thermocycling. One week after bonding shearing for…
Haemostatic agents on the shear bond strength of self-adhesive resin
2015
Background Dentin surface contaminated with haemostatic agents can interfere with the bonding of self-adhesive resin cement. Therefore the purpose of this study was to evaluate the effect of various haemostatic agents such as Aluminium chloride, Ferric sulphate and Tannic acid on the shear bond strength of self-adhesive resin luting agent. Material and Methods The buccal surfaces of extracted premolars were flattened to expose the dentine. The teeth were then randomly divided into four groups. In Group I Aluminium Chloride was applied on the flattened dentinal surface, in Group II Ferric Sulphate was applied to exposed dentin surface, in Group III tannic acid was applied on to the dentinal …
Convolution-based ensemble learning algorithms to estimate the bond strength of the corroded reinforced concrete
2022
Reinforced concrete bond strength deterioration is one of the most serious problems in the construction industry. It is one of the most common factors impacting structural deterioration and the major cause of premature decadence of reinforced concrete structures. Therefore, developing an accurate model with the lowest variance and high reliability for the bond strength of corroded reinforced concrete is very important. The current work evaluates the efficiency of convolution-based ensemble learning algorithms. To address these issues, convolution-based ensemble learning models are developed using a database collected from the previous experimental studies of relative bond strength for corro…
Steel-concrete bond in lightweight fiber reinforced concrete under monotonic and cyclic actions
2005
Experimental results of the local bond stress-slip relationship of reinforcing bars embedded in lightweight fiber reinforced concrete with expanded clay aggregates are presented. The effect of the following parameters were investigated: - dimension of specimens; - anchorage length; - percentages of hooked steel fibers; - geometrical ratio of transverse reinforcement; - confinement external transverse pressure. Prismatic specimens with deformed steel bars embedded for a fixed length equal to five and eight equivalent diameters were tested under both monotonic and cyclic reversal imposed displacements at the tip of the bars, in controlled displacement tests. The influence of the above mention…